An employee shall receive additional training (or retraining) under any of the following conditions:ġ. Unqualified persons shall be trained in, and be familiar with, any electrical safety-related practices necessary for their safety.Īrticle 110.2(D)(3) Retraining. Requirements For The Training Of Unqualified PersonsĪrticle 110.2(D)(2) Unqualified Persons. The standard also now includes use of GFCIs where required by local, state and federal codes or standards. According to OSHA 1910, the definition of qualified includes required training, demonstrated skills, and knowledge of installation and hazards. Regarding use of equipment, Article 110.4 now specifies that only qualified persons perform testing and maintenance within the limited approach boundary. These changes supersede any previous additions. Also, any changes as a result of a new cycle of the 70E need to be updated. The audit also must be documented and revisions made to the safety program if any elements are not in compliance. What’s more, facility owners must now audit their safety training program and field work at least every 3 years to ensure it complies with 70E. As far as OSHA is concerned, if not documented, compliance wasn’t achieved. And Article 110.2(D)(3) requires that employees be retrained at intervals not to exceed 3 years, while 110.2(E) states that the training content must be documented. Article 110.2(D)(1)(f) requires employers to perform annual inspections (audit) to ensure each employee is complying with all safety-related work practices outlined in 70E. The 70E standard also adds emphasis to its provision that employees who work around (not just on) energized electrical equipment must be safety trained. However, Article 110.1(C) requires this meeting to be documented. Some facility managers already comply with the requirement that employers meet with contractors to communicate known hazards and information about the facility installation that the contractor needs to make assessments. The article then provides specifics on what is required, including specifying the requirements for qualified person and unqualified person training. Employees shall be trained to identify and understand the relationship between electrical hazards and possible injury.” They shall be trained in safety-related work practices and procedural requirements, as necessary to provide protection from the electrical hazard associated with their respective job or task assignment. The introduction to this section provides a summary of the arc flash training requirements: “Such employees shall be trained to understand the specific hazards associated with electrical energy. Article 110.2 of NFPA 70E 2018 specifies the safety training requirements when working on equipment that presents an electrical hazard.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |